Fire Safety Name of the Student Course Title Institution Date of Submission Fire Safety Through recorded standards incorporating the International Fire Service Training Association

Fire Safety Name of the Student Course Title Institution Date of Submission Fire Safety Through recorded standards incorporating the International Fire Service Training Association (IFSTA), stages of fire are incipient, growth, fully developed, plus decay. Identifying the phases of fire progression and possible development in this process enables firefighters to forecast on the next possible happenings, possible changes because of unplanned ventilation, and the possible impact of tactical action. Incipient this is the initial phase that starts when oxygen, heat, and a source of fuel combine and create a chemical reaction ending up in fire. The stage is also referred to as ignition, and a very small fire illustrates it which regularly goes out by itself prior to reaching the other phases. Realizing fire at this stage gives a person the best opportunity to escape (Josh, September 27, 2010). Growth stage comes second, whereby arrangements fire load plus oxygen are executed as fire fuel. A number of factors impact the growth phase for example the location where fire originated, combustibles close to it, height of the ceiling and possibility of thermal layering. At this stage, fatal flashover might happen possibly trapping, hurting or even killing firefighters. The third phase is fully developed, where once this stage is gotten its maximum and entire combustible matters have been burnt, and by now fire is said to be fully developed. The hottest between the four fire stages is this one, which is also said to be the most dangerous to any person trapped in (Josh, September 27, 2010). The final phase of a fire is decay. Normally, this stage is the longest is the stages of fire, which is regarded as a noteworthy reduction in fuel or oxygen, bringing end of the fire. The two usual threats at this phase are the presence of non-flaming combustibles that can possibly begin a fresh fire lest is completely extinguished, and two, there is the threat of a backdraft once oxygen is reestablished to a volatile, restrained space (Josh, September 27, 2010). The phases of a full detailed inspection program for fire-alarm plus detection system consist of visual inspections, system testing, maintenance, and records. The first stage visual inspection makes sure no system changes or associated equipment affect performance of the system. What inspectors are supposed to visually inspect are fire-alarm control units including their components, fire-alarm boxes, heat detectors, plus water-flow devices, remote annunciator panels, and alarm-notification devices. The aim of inspections is to detect problematic situations like disconnected wiring at fire-alarm panels (Ray, January 22, 2010). The second stage is to test systems to conform to NFPA 72. Technicians have to test components of the system at the prerequisite intervals and applying testing techniques as indicated by the NFPA Standard 72. Importance of testing is that it assists checking a number of system functions as well as components. Based on the time of life if the detection system and fire-alarm, system modifications, plus facility conditions, managers may be required to be attentive to entire system maintenance, which is the next stage. Maintenance can range from simple activities like cleaning smoke-detector intuiting chambers to replacing invalid fire-alarm panels (Ray, January 22, 2010). Records is the final stage, incorporating systems initial as-built shop diagrams, operation plus maintenance guidebooks, as well as the written operations sequence, offer system operation and outline information for the testing agency. This record is important, mostly once the fire-alarm and detection system borders to other equipment in the building (Ray, January 22, 2010). References Josh. (September 27, 2010). The 4 Stages of a Fire. Journey to Firefighter. Retrieved from HYPERLINK https//journeytofirefighter.com/4-stages-of-a-fire/ https//journeytofirefighter.com/4-stages-of-a-fire/ Ray, L. (January 22, 2010). Fire Safety The Goals of Visual Inspections. Facilitiesnet. Retrieved from HYPERLINK https//www.facilitiesnet.com/firesafety/article/Fire-Safety-The-Goals-of-Visual-Inspections–11439sourceprevious https//www.facilitiesnet.com/firesafety/article/Fire-Safety-The-Goals-of-Visual-Inspections–11439sourceprevious FIRE SAFETY PAGE MERGEFORMAT 2 Running head FIRE SAFETY PAGE MERGEFORMAT 1 Y, dXiJ(x(I_TS1EZBmU/xYy5g/GMGeD3Vqq8K)fw9
xrxwrTZaGy8IjbRcXI
u3KGnD1NIBs
RuKV.ELM2fiVvlu8zH
(W uV4(Tn
7_m-UBww_8(/0hFL)7iAs),Qg20ppf DU4p
MDBJlC5
2FhsFYn3E6945Z5k8Fmw-dznZxJZp/P,)KQk5qpN8KGbe Sd17 paSR 6Q